Home Performance Assessment

Randy performs duct testing.

Randy performs duct testing.

1. Building Inspection

  • Building envelope – walls, windows, doors, floors and ceilings
  • Including – crawlspace, attic, garage and other attached zones
  • Equipment – heating system, ducting, ventilation, hot water, lighting

2. Identification of possible moisture, mold, dust or other indoor air quality problems

3. Pressure Diagnostics

  • Blower door test to quantify total air leakage and find air leakage sites
  • Assess current natural ventilation rate
  • Zone measurements to determine infiltration rates from crawlspace, attic, garage

4. Heating duct efficiency test – duct leakage and flow

5. Combustion safety & carbon monoxide – furnace, water tank fireplace or dryer

6. Infrared Scan of Building Envelope

  • Identifies insulation deficiencies
  • Pinpoints hidden air leakage pathways
  • Finds ducts and electrical equipment hidden within building cavities

7. Action Plan to bring your home to a high standard of energy efficiency, comfort and air quality, based on your priorities and our findings. Report includes all test results, conclusions, infrared photos and recommendations for improvements.